What will the DuroMax XP13000HXT run?
The DuroMax XP13000HXT makes 10,500 running watts and 13,000 starting watts on gasoline, propane or natural gas. On the generator makers' wattage charts that runs a well pump, a sump pump, a furnace blower, a refrigerator, a freezer, a microwave, lights, Wi-Fi and a TV at the same time, using about 5,846 of its watts.
At 10,500 running watts on gasoline (10,000 propane, 9,000 natural gas) it has room for a refrigerator, freezer, furnace blower, well or sump pump and a window air conditioner or two. It has L14-30R and 14-50R outlets for a transfer switch or interlock, and the maker lists CO Alert shutdown and a natural gas hose in the box.
Outage combinations
| Running at once | Running W | Runs it? |
|---|---|---|
| Refrigerator, lights, Wi-Fi, TV and phones | 1,046 | Yes |
| Gas furnace blower, refrigerator, lights and Wi-Fi (wired in) | 1,428 | Yes |
| Sump pump, refrigerator, lights and Wi-Fi | 1,828 | Yes |
| Window air conditioner, refrigerator, lights and Wi-Fi | 2,028 | Yes |
| Well pump, refrigerator and lights (wired in) | 1,810 | Yes |
| Refrigerator, microwave and coffee maker | 3,450 | Yes |
| CPAP with humidifier, refrigerator, lights and phones | 947 | Yes |
| Furnace blower, refrigerator, freezer, sump pump, lights, Wi-Fi and TV (wired in) | 3,326 | Yes |
| Well pump, sump pump, furnace blower, refrigerator, freezer, microwave, lights, Wi-Fi and TV (wired in) | 5,846 | Yes |
| Electric water heater, refrigerator, furnace blower and lights (wired in) | 6,410 | Yes |
| 3-ton central air conditioner (wired in) | 6,000 | No |
One appliance at a time
| Appliance | Running W | Runs it? |
|---|---|---|
| Refrigerator | 750 | Yes |
| Freezer (chest or upright) | 750 | Yes |
| Gas furnace blower (1/3 to 1/2 HP) | 600 | Yes |
| Sump pump (1/2 HP) | 1,000 | Yes |
| Well pump (1/3 to 1/2 HP) | 1,000 | Yes |
| Window air conditioner (10,000 BTU) | 1,200 | Yes |
| Microwave | 1,500 | Yes |
| Coffee maker | 1,200 | Yes |
| Electric space heater | 1,500 | Yes |
| CPAP with heated humidifier (and heated tube) | 67 | Yes |
| Home oxygen concentrator | 325 | Yes |
| Electric water heater (50 gallon, 240V) | 5,000 | Yes |
| Central air conditioner (3 ton) | 6,000 | No |
Cautious running and starting watts from Champion's and DTE Energy's wattage charts. "Check": it runs once started, but the charts' start-up surge is more than its 13,000 starting watts, so read your appliance's label (amps × 120 = watts). Wired-in loads need a transfer switch fitted by a qualified electrician. Your own list: the generator calculator.
Questions
Can the DuroMax XP13000HXT run a refrigerator?
Yes. A refrigerator needs up to about 750 running watts and 2,600 to start on the charts, within its 10,500 running and 13,000 starting watts.
Can the DuroMax XP13000HXT run a well pump?
Yes. A 1/3 to 1/2 HP well pump needs up to about 1,000 running watts and 3,000 to start on the charts, within its 10,500 running and 13,000 starting watts. A well pump is wired in, so it needs a transfer switch fitted by a qualified electrician.
Can the DuroMax XP13000HXT run central air?
No. DTE Energy's guide puts a 3-ton central air conditioner at 6,000 running watts and about 18,000 watts to start. That takes a standby generator.