PreparedStates

What will the Honda EU7000iS run?

The Honda EU7000iS makes 5,500 running watts and 7,000 starting watts on gasoline. On the generator makers' wattage charts that runs a furnace blower, a refrigerator, a freezer, a sump pump, lights, Wi-Fi and a TV at the same time, using about 3,326 of its watts.

Honda EU7000iS 5,500-Watt Gasoline Inverter Portable Generator, with CO-MINDER (49-State)
5,500W running · 7,000W starting · Gasoline · 263 lb

At 5,500 rated watts (7,000 maximum) it can run a refrigerator, furnace blower and sump pump with lights, and a window air conditioner as the biggest add. Honda lists a 30A 125/250V locking outlet for a transfer-switch cord, and CO-MINDER is the maker's term for its carbon monoxide shutoff.

See price on Amazon

Outage combinations

Running at onceRunning WRuns it?
Refrigerator, lights, Wi-Fi, TV and phones1,046Yes
Gas furnace blower, refrigerator, lights and Wi-Fi (wired in)1,428Yes
Sump pump, refrigerator, lights and Wi-Fi1,828Yes
Window air conditioner, refrigerator, lights and Wi-Fi2,028Yes
Well pump, refrigerator and lights (wired in)1,810Yes
Refrigerator, microwave and coffee maker3,450Yes
CPAP with humidifier, refrigerator, lights and phones947Yes
Furnace blower, refrigerator, freezer, sump pump, lights, Wi-Fi and TV (wired in)3,326Yes
Well pump, sump pump, furnace blower, refrigerator, freezer, microwave, lights, Wi-Fi and TV (wired in)5,846No
Electric water heater, refrigerator, furnace blower and lights (wired in)6,410No
3-ton central air conditioner (wired in)6,000No

One appliance at a time

ApplianceRunning WRuns it?
Refrigerator750Yes
Freezer (chest or upright)750Yes
Gas furnace blower (1/3 to 1/2 HP)600Yes
Sump pump (1/2 HP)1,000Yes
Well pump (1/3 to 1/2 HP)1,000Yes
Window air conditioner (10,000 BTU)1,200Yes
Microwave1,500Yes
Coffee maker1,200Yes
Electric space heater1,500Yes
CPAP with heated humidifier (and heated tube)67Yes
Home oxygen concentrator325Yes
Electric water heater (50 gallon, 240V)5,000Yes
Central air conditioner (3 ton)6,000No

Cautious running and starting watts from Champion's and DTE Energy's wattage charts. "Check": it runs once started, but the charts' start-up surge is more than its 7,000 starting watts, so read your appliance's label (amps × 120 = watts). Wired-in loads need a transfer switch fitted by a qualified electrician. Your own list: the generator calculator.

Questions

Can the Honda EU7000iS run a refrigerator?

Yes. A refrigerator needs up to about 750 running watts and 2,600 to start on the charts, within its 5,500 running and 7,000 starting watts.

Can the Honda EU7000iS run a well pump?

Yes. A 1/3 to 1/2 HP well pump needs up to about 1,000 running watts and 3,000 to start on the charts, within its 5,500 running and 7,000 starting watts. A well pump is wired in, so it needs a transfer switch fitted by a qualified electrician.

Can the Honda EU7000iS run central air?

No. DTE Energy's guide puts a 3-ton central air conditioner at 6,000 running watts and about 18,000 watts to start. That takes a standby generator.

More on the Honda EU7000iS