What will the Champion 201318 run?

The Champion 201318 makes 3,500 running watts and 4,500 starting watts on gasoline. On the generator makers' wattage charts that runs a refrigerator, lights, Wi-Fi, a TV and phones at the same time, using about 1,046 of its watts.

Champion 201318 4,500-Watt RV Ready Portable Inverter Generator with CO Sensor
3,500W running · 4,500W starting · Gasoline · 92.2 lb

A 4,500-watt Champion inverter with a 120V 29.2A RV outlet and a 20A household duplex. The listing gives up to 14 hours on 2.3 gallons of gasoline, load not stated, and 61 dBA. It lists a CO Sensor.

See price on Amazon

Outage combinations

Running at onceRunning WRuns it?
Refrigerator, lights, Wi-Fi, TV and phones1,046Yes
Gas furnace blower, refrigerator, lights and Wi-Fi (wired in)1,428Yes
Sump pump, refrigerator, lights and Wi-Fi1,828Yes
Window air conditioner, refrigerator, lights and Wi-Fi2,028Yes
Well pump, refrigerator and lights (wired in)1,810Yes
Refrigerator, microwave and coffee maker3,450Check
CPAP with humidifier, refrigerator, lights and phones947Yes
Furnace blower, refrigerator, freezer, sump pump, lights, Wi-Fi and TV (wired in)3,326Check
Well pump, sump pump, furnace blower, refrigerator, freezer, microwave, lights, Wi-Fi and TV (wired in)5,846No
Electric water heater, refrigerator, furnace blower and lights (wired in)6,410No
3-ton central air conditioner (wired in)6,000No

One appliance at a time

ApplianceRunning WRuns it?
Refrigerator750Yes
Freezer (chest or upright)750Yes
Gas furnace blower (1/3 to 1/2 HP)600Yes
Sump pump (1/2 HP)1,000Yes
Well pump (1/3 to 1/2 HP)1,000Yes
Window air conditioner (10,000 BTU)1,200Yes
Microwave1,500Yes
Coffee maker1,200Yes
Electric space heater1,500Yes
CPAP with heated humidifier (and heated tube)67Yes
Home oxygen concentrator325Yes
Electric water heater (50 gallon, 240V)5,000No
Central air conditioner (3 ton)6,000No

Cautious running and starting watts from Champion's and DTE Energy's wattage charts. "Check": it runs once started, but the charts' start-up surge is more than its 4,500 starting watts, so read your appliance's label (amps × 120 = watts). Wired-in loads need a transfer switch fitted by a qualified electrician. Your own list: the generator calculator.

Questions

Can the Champion 201318 run a refrigerator?

Yes. A refrigerator needs up to about 750 running watts and 2,600 to start on the charts, within its 3,500 running and 4,500 starting watts.

Can the Champion 201318 run a well pump?

Yes. A 1/3 to 1/2 HP well pump needs up to about 1,000 running watts and 3,000 to start on the charts, within its 3,500 running and 4,500 starting watts. A well pump is wired in, so it needs a transfer switch fitted by a qualified electrician.

Can the Champion 201318 run central air?

No. DTE Energy's guide puts a 3-ton central air conditioner at 6,000 running watts and about 18,000 watts to start. That takes a standby generator.